CERTIFICATE

OF COMPLIANCE

Lapitec Spa

Lapitec

80481-420

Certificate Number

07/11/2016 - 07/11/2020

Certificate Period

Certified

Status

UL 2818 - 2013 Gold Standard for Chemical Emissions for Building Materials, Finishes and Furnishings

Wall finishes are determined compliant in accordance with California Department of Public Health (CDPH) Standard Method V1.2-2017 using a Classroom Environment with an air change of 0.82 hr ̄ 1 and a loading of

94.60 m2. ; and Wall finishes are determined compliant in accordance with California Department of Public Health (CDPH) Standard Method V1.2-2017 using an Office Environment with an air change of 0.68 hr ̄ 1 and a

loading of 33.40 m2.

Product tested in accordance with UL 2821 test method to show compliance to emission limits on UL 2818. Section 7.1 and 7.2.

GREENGUARD Gold Certification Criteria for Building Products and Interior Finishes

UL investigated representative sa

Holder (collectively

Criteria

CAS Number

Maximum Allowable

Predicted Concentration

Units

TVOC

(A)

-

0.22

mg/m3

Formaldehyde

mples of the identified Product(s) to the identified Standard(s) or other requiremen

lder is authorized to use the UL Mark for the identified Product(s) manufactured at

50-00-0

ts in accordance with the agre

the production site(s) covered

9 (7.3 ppb)

ements and any applicable program service terms in plac

by the UL Test Report, in accordance with the terms of th

μg/m3

e between UL and the Certificate

e Agreement. This Certificate is v

nce with the Agreement.

Total Aldehydes

(B)

-

0.043

ppm

4-Phenylcyclohexene

4994-16-5

6.5

μg/m3

Particle Matter less than 10 μm

(C)

-

20

μg/m3

1-Methyl-2-pyrrolidinone

(D)

872-50-4

160

μg/m3

Individual VOCs

(E)

-

1/2 CREL

or

1/100th TLV

-

“Agreement”). The Certificate Ho

dates unless there is non-complia

alid for the identified

(A)

(B)

(C)

(D)

(E)

Defined to be the total response of measured VOCs falling within the C6 – C16 range, with responses calibrated to a toluene surrogate. Maximum

allowable predicted TVOC concentrations for GREENGUARD Gold (0.22 mg/m3) fall in the range of 0.5 mg/m3 or less, as specified in CDPH Standard

Method v1.2.

The sum of all measured normal aldehydes from formaldehyde through nonanal, plus benzaldehyde, individually calibrated to a compound specific

standard. Heptanal through nonanal are measured via TD/GC/MS analysis and the remaining aldehydes are measured using HPLC/UV analysis.

Particle emission requirement only applicable to HVAC Duct Products with exposed surface area in air streams (a forced air test with specific test

method) and for wood finishing (sanding) systems.

Based on the CA Prop 65 Maximum Allowable Dose Level for inhalation of 3,200 μg/day and an inhalation rate of 20 m3/day

Allowable levels for chemicals not listed are derived from the lower of 1/2 the California Office of Environmental Health Hazard Assessment (OEHHA)

Chronic Reference Exposure Level (CREL) as required per the CDPH/EHLB/Standard Method v1.2 and BIFMA level credit 7.6.2 and 1/100th of the

Threshold Limit Value (TLV) industrial work place standard (Reference: American Conference of Government Industrial Hygienists, 6500 Glenway,

Building D-7, and Cincinnati, OH 45211-4438).

UL investigated representative samples of the identified Product(s) to the identified Standard(s) or other requirements in accordance with the agreements and any applicable program service terms in place between UL and the Certificate Holder (collectively

“Agreement”). The Certificate Holder is authorized to use the UL Mark for the identified Product(s) manufactured at the production site(s) covered by the UL Test Report, in accordance with the terms of the Agreement. This Certificate is valid for the identified

dates unless there is non-compliance with the Agreement.